Digestion & dilution calculator

result = reading × factor × V_digest / m_sample

Enter the sample, the volume the digest was made up to, each dilution step and the instrument reading. The concentration in the original sample appears with every step of the calculation shown.

Sample

Digestion / extraction

The volume the digest or extract was brought to.

Dilution steps

Instrument reading

Result

Report in

Instrument reading back to the sample

About this calculation

Runs in your browser

The calculation runs in your browser. Your inputs are kept in this browser's storage on this device so they are still here when you come back; Clear removes them.

Checked

Checked against: a hand-worked soil digestion with one dilution step, each unit of reading and result, a blank, a dry-weight basis, a liquid sample and the refusal of impossible chains.

Calculation version 088929cdc6c2, shared with the Android app.

Worked example

0.25 g of soil is digested and made up to 50 mL. 1 mL of the digest is diluted to 10 mL, and the instrument reads 25 µg/L.

dilution factor 10 → digest 250 µg/L = 0.25 mg/L → 0.25 mg/L × 0.050 L = 0.0125 mg → 0.0125 mg / 0.00025 kg = 50 mg/kg

The same chain as one factor: the reading is multiplied by ×2 (µg/L to mg/kg). The Load example button fills in these values.

Formula

  • Blank-corrected reading = reading − blank
  • Dilution factor = made-up volume ÷ aliquot, multiplied across every step
  • In the digest = blank-corrected reading × dilution factor
  • Analyte mass = digest concentration × digest volume
  • Result = analyte mass ÷ sample amount

Dry-weight basis: dry mass = weighed mass × (1 − moisture ÷ 100), with the moisture on a wet basis. Drying removes water but not analyte, so the dry-basis result is always the higher number.

Assumptions and limits

  • Enable the blank only when your SOP requires subtraction. Do not enter a blank if the instrument software or the LIMS has already corrected the reading.
  • A dilution step made up to less than the aliquot taken is rejected, not calculated: it is not a dilution, and it is almost always two numbers entered the wrong way round.
  • Units: µg/L and ng/mL are the same number, as are mg/L and µg/mL, and mg/kg and µg/g. Both spellings are offered so that you can enter what the instrument shows. 1 % (m/m) = 10 000 mg/kg.
  • No recovery or spike correction is applied. Many methods report results uncorrected, and applying one silently would change what the number means.
  • The notes the calculator gives, each in one line: an analyte mass larger than the sample (usually a reading unit one step out, by exactly 1000), a zero or negative reading, a reading at or below the blank, a dilution factor of 1000 or more, a test portion below 50 mg or a liquid sample below 100 µL, and a moisture of 95 % or more on a dry basis.
  • The result carries no measurement uncertainty: balance, pipettes and flasks each add their own, the smallest aliquot most of all in relative terms.

References

The relations are definitions of dilution factor, concentration and mass fraction, and use no tabulated data. The thresholds of the notes are those recorded in the LabTools Android app.

The calculation is the one used by the Digestion & Dilution calculator in the app, where saved method presets and the longer explanation of each note are part of PRO.