Free online calculators for analytical chemists

Laboratory calculations you can defend.

13 laboratory calculators and 44 unit converters, free in your browser: calibration with LOD and LOQ, dilutions, buffers, HPLC and ICP preparation. Each one shows its formula, its assumptions and its references.

Calculated in your browser. What you type is not uploaded, and there is no account.

From one step to the next

Calculations that lead into each other.

A stock becomes working standards, the standards become a curve, the curve becomes a result. The calculators below are the ones on this site; a step marked Android · PRO is a module of the app that the web does not have.

Your samples are your business

Your numbers stay in your browser.

Calculated in your browser

The numbers you type and the results never leave the page. They are not sent to a server and not put in the address.

Kept on this device only

To save you retyping, the last values are remembered in this browser, and you can save up to 50 calculations. Clear, or your browser settings, delete them.

No account, no cookies

There is nothing to sign up for. The site counts page views with Cloudflare Web Analytics, which sets no cookies and never sees your inputs.

The privacy policy for this website →
LabTools for Android

The full toolkit, in your pocket.

40 focused modules for the analytical lab: calibration and validation statistics, HPLC and ICP tools, QC charts and guided instrument troubleshooting.

  • The calculators of the web, with your results kept in an archive on the phone.
  • The full diagnostic explanations behind every flag (PRO), in seven languages.
  • PDF, Excel and CSV reports with your own template (PRO).
  • The modules that need a subscription: method validation, HPLC and GC method transfer, HRMS formula prediction, instrument troubleshooting (PRO).

Android 7.0 or newer · 7 languages · No account needed

LabTools Calibration Curve on a phone: seven lead standards from 0.5 to 50 ppb with a 1/x weighted fit, y = 31.2165x + 0.245957, R² 0.999956, and every standard within ±0.86 % relative error, dark theme

Max %RE

±0.86 %

1/x weighted fit

LOD / LOQ

0.115 / 0.347 ppb

ICH Q2(R2), from the curve

Pb in the sample

8.603 ± 0.128 ppb

95 % confidence, 3 readings

App theme

40

focused modules

across four Home categories

44

unit converters

general and specialized

7

languages

decimal commas where they belong

44

troubleshooting paths

across 7 instrument types

Every result shows its working. Units follow the data. And when a number is arithmetically right but practically risky, LabTools says so.

Worked example · ICP-MS

One calibration, start to finish

Lead in drinking water by ICP-MS: a routine trace-metal calibration with a classic trap in it. Every value below was typed into LabTools on a real Android phone, and every screen is a capture of what the app showed.

Calibration method and sourcesUnderstanding LOD and LOQ

  1. Step 1 of 7

    Seven standards, units typed once

    Seven lead standards from 0.5 to 50 µg/L (ppb), with the ICP-MS signal in kcps. The units are typed once and follow the data into the chart, the equation and every result. Each standard has its own include box, so a suspect point can leave the regression without being deleted.

    Standards input with seven rows, concentration in ppb and signal in kcps, dark theme
  2. Step 2 of 7

    R² = 0.999971, and still wrong at the low end

    An unweighted fit lets the 50 µg/L standard dominate. Back-calculating every standard shows the problem: 0.5 µg/L comes out 11.26 % high, 1 µg/L 5.77 % high, and the fit pulls the intercept down to −1.48 kcps, an offset worth about 9 % of the 0.5 µg/L signal. R² alone would have passed this curve.

    Unweighted fit: R² 0.999971, but %RE of +11.26 % and +5.77 % for the two lowest standards and a negative intercept, dark theme
  3. Step 3 of 7

    The app says why, and what not to do

    Diagnosis names standard #1, lists what to check (standard preparation, blank and intercept, injection, working range) and suggests comparing 1/x or 1/x² weighting. It also warns against using weighting or exclusion only to make a curve pass. The full explanation is part of PRO; the free version shows its one-line summary.

    Expanded Diagnosis card explaining the 11.26 % error of standard #1 and suggesting 1/x or 1/x² weighting, dark theme
  4. Step 4 of 7

    1/x weighting, one tap

    1/x weighting gives the low standards more influence, as appropriate when signal variance is proportional to concentration. Every standard now back-calculates within ±0.86 %, R² stays at 0.999956, and the intercept moves to +0.246 kcps, close to zero.

    1/x weighted fit: y = 31.2165x + 0.245957, every standard within ±0.86 % relative error, dark theme
  5. Step 5 of 7

    An unknown, with an honest interval

    Three readings of the drinking-water sample average 268.8 kcps. The curve returns 8.603 ± 0.128 µg/L at 95 % confidence, shows s(x₀), t and the degrees of freedom behind the interval, and confirms the result lies inside the calibrated range.

    Unknown sample: measured signal 268.8 kcps over 3 readings, calculated concentration 8.603 ppb ± 0.1283 ppb, within the calibration range, dark theme
  6. Step 6 of 7

    LOD and LOQ from the curve itself

    The ICH Q2(R2) calibration-curve approach, with the residual SD weighted exactly like the fit: LOD 0.115 µg/L and LOQ 0.347 µg/L. The LOQ falls below the lowest standard (0.5 µg/L), so confirm it with a spiked sample before reporting results that low. Method Validation can pull these values straight in.

    LOD/LOQ section: residual SD 1.084 kcps (n=7), LOD 0.1146 ppb, LOQ 0.3474 ppb, dark theme
  7. Step 7 of 7

    Then file it, or send it

    Save the curve to the searchable archive, or share it as a PDF report with the chart, an Excel table or a CSV table. Export is part of PRO.

    Export format picker offering Excel table, PDF report and CSV table, dark theme
App theme

Everything on the Home screen

40 modules, plus unit conversion

Grouped the way the app groups them. Modules marked PRO need the subscription once the 7-day trial ends; everything else stays free.

    • Linear regression with 1/x or 1/x² weighting, %RE per point, an unknown with a 95 % interval and ICH Q2(R2) LOD/LOQ.

    • Takes an ICP-MS, ICP-OES, AAS or IC reading back through every dilution step to the original sample, with blank subtraction and dry-weight basis.

    • C₁·V₁ = C₂·V₂ with a plain-language instruction, a percent mode and a lookup for concentrated acids and ammonia.

    • Solves A = ε·l·c for whichever value is missing and flags absorbance above 2.0 as possibly non-linear.

    • C = m / (M·V) and normality, with molar mass worked out from formulas such as CuSO4·5H2O or K4[Fe(CN)6].

    • Multi-solvent blends by volume or weight, additives as %, stock or solid, and a tick-off bottle checklist.

    • Acid and base amounts for 14 buffer systems, from citrate and phosphate to HEPES and CHES, with temperature correction.

    • Mass to weigh, corrected for purity and salt form, from a 203-compound database, with solubility and flask-fill warnings.

    • Run time, finish time, eluent and suppressor water with a 10 % margin for an ion chromatography sequence.

    • How long Ar, He, N₂ and H₂ cylinders last, using real-gas data, with a weekend reserve and change-over pressure.

    • Instrument loads in W, VA or A, phase balancing, breaker size and a UPS rating, as a planning estimate.

    • Column volume, flush volume and flush time; dead volume, t₀ and linear velocity checked against your measured value.

      Dead-volume tab is PRO

    • Total dissolved solids for ICP-OES and ICP-MS samples, from conductivity or 17 sample templates, with a recommended dilution.

    • Scales isocratic and gradient methods to a new column, corrects for gradient delay and predicts resolution and pressure.

    • Checks whether an injection's vapor fits the inlet liner, for 17 solvents and common liners.

    • Candidate formulas within a ppm window for 11 ion types ([M+H]⁺, [M+Na]⁺, [M−H]⁻ …), filtered by the Seven Golden Rules, with DBE.

    • Polyatomic interferences for 142 isotopes of 56 elements, with a recommended cell or correction mode.

    • 1,449 analytical lines across 79 elements, with NIST-based overlaps and a zoomable overlap chart.

    • Counts colonies (CFU/mL) or hemocytometer cells from a photo, on the phone, with markers you can correct by hand.

    • Rs, N, HETP, h, k′ and α per USP <621>, with a diagnosis of what is limiting the separation.

    • Pressure drop for fully porous and core-shell columns, with automatic water/methanol and water/acetonitrile viscosity.

    • The shear-rate and stress window a rheometer geometry can actually measure, and what limits each end.

    • Translate a GC method across carrier gases or columns, with flow, pressure and oven programme estimates.

    • Estimate headspace conditions and pressure for a GC vial before running the method.

    • Plan an ultracentrifuge run from rotor and speed parameters.

    • Estimate ion chromatography column loading and capacity.

    • Estimate pressure during microwave digestion from sample preparation conditions.

    • Mean, SD and RSD with Grubbs' outlier test and Horwitz/HorRat, from typed, pasted or camera-scanned values.

    • Compares two series: F-test, then a Student or Welch t-test, with Grubbs' check and Cohen's d.

    • Recovery, linearity, bias, uncertainty, z-score, HorRat and LOD/LOQ, in one PDF report with signature fields.

    • Levey-Jennings charts read by seven Westgard rules, across control levels and lots.

      Free: one profile

    • Review batch QC results and document the decision in a report.

    • DEG/RAD, hyperbolic functions, scientific notation, memory keys, fractions and a history.

    • A lap stopwatch and a countdown timer with sound and a background notification.

    • Uses the phone's motion sensors, with rising audio beeps, as an aid for leveling an instrument.

    • Maintenance tasks marked On track, Due soon or Overdue, with reminders on the due date and a week before.

    • All 118 elements with search, filters, element details and a molar mass calculator.

    • Wavelength, wavenumber, frequency and photon energy on a zoomable spectrum from 1 fm to 100 km.

    • Yes/No guides for AAS, FTIR, GC, HPLC, IC, ICP-MS and ICP-OES, ending in a fix or a call to service.

    • One searchable archive for saved results, with PDF export in PRO.

      Free: latest 3

    • 44 converters covering general and laboratory quantities, including viscosity, Brix, RPM ↔ RCF, radiation dose and gas concentration.

Real screens

More of the app, as it really looks

Captured from the same phone, with real inputs. Swipe through, or flip the theme.

App theme
  • LabTools compact home screen with four calculator categories and unit conversion, dark theme

    Home

    40 modules in four categories, plus 44 unit converters. Search in seven languages.

  • QC Control Chart verdict Out of control by rule 2-2s, with a Levey-Jennings chart whose last point is circled, dark theme

    QC Control Chart

    Both control levels beyond +2 SD in the same run: 2-2s, out of control, systematic error.

  • HPLC troubleshooting guide showing the steps taken and the next Yes/No question, dark theme

    HPLC troubleshooting

    PRO

    A Yes/No path for tailing, fronting or split peaks that keeps the steps you have taken.

  • Formula Prediction results: C8H10N4O2 at 0.010 ppm and C8H18OS2 at 2.401 ppm, dark theme

    Formula Prediction (HRMS)

    PRO

    m/z 195.08765 as [M+H]⁺ within 5 ppm: C₈H₁₀N₄O₂ at 0.010 ppm, DBE 6.

  • Peak Performance results: resolution 1.32 with a warning, diagnosis that selectivity limits the separation, dark theme

    Peak Performance

    PRO

    Rs 1.32 flagged as a warning, with selectivity (α = 1.046) named as the limiting factor.

  • Method Transfer savings chart and gradient profile for the reference and target columns, dark theme

    Method Transfer (HPLC)

    PRO

    150 × 4.6 mm, 5 µm to 100 × 2.1 mm, 1.8 µm: 76 % less time, 86 % less eluent, 90 % less sample.

  • LabTools periodic table with 118 elements, dark theme

    Periodic table

    118 elements, color-coded by category, with search, favorites and a molar mass calculator.

Built for the bench, not the brochure

Why the numbers hold up

Units stay explicit

Inputs carry their units and results come back with them, so µg/L never quietly becomes mg/L.

A diagnosis, not a silent pass

Risky results, like the 0.5 µg/L standard that read 11 % high, come with an explanation and a list of what to check.

Cross-checked science

Formulas are tested against independent reference implementations and published worked examples; reference data is checked against its sources.

Archive and reports

Results go to one searchable archive. With PRO, export PDF reports with your logo, accreditation, operator and signature blocks, or Excel and CSV tables.

Your data stays on the phone

No account, no ad libraries, and Android cloud backup is off. Anonymous analytics are opt-in, off by default, and never include inputs or results.

7 languages

English, Deutsch, Français, Español, 日本語, 中文 and Русский, picked from your phone, with decimal commas where your language uses them.

Free & PRO

Free to install. PRO when you need it.

Every install starts with a 7-day trial of everything. When it ends you keep the free version; no subscription starts on its own.

Free

20 tools, including unit conversion

  • Calibration Curve, Dilution, Mass / Molarity, pH Buffer Prep, Mobile Phase Mixer, Digestion & Dilution and Lambert-Beer Law
  • Gas Consumption, Lab Power & UPS, TDS (ICP) and Column & Dead Volume (Flush & Geometry tab)
  • QC Control Chart with one profile; the chart shows the latest 15 runs while the rules read the full history
  • Scientific Calculator, Periodic Table, Spectrum Reference, Instrument Scheduler, Stopwatch / Timer, Lab Leveler and Unit Converter with 44 converters
  • Archive with your latest 3 results
  • Diagnosis cards with their one-line summary

PRO

Monthly or annual subscription, priced in Google Play

  • All 21 PRO modules, including HRMS formula prediction, HPLC and GC method transfer, headspace optimization, batch QC review, ICP interferences and instrument troubleshooting
  • PDF reports, Excel and CSV export
  • Full diagnostic hints in every calculator
  • Full archive with PDF export
  • Multiple QC profiles, full chart history and chart export
  • Method presets, the dead-volume tab and alternate app icons
  • Every future PRO tool, included

FAQ

Questions, answered

  • They are free, need no account and run in your browser: what you type is not sent to us or put in the page address. To save you retyping, the last values and the calculations you choose to save are kept in your browser's storage on that device, and Clear or your browser settings remove them.

  • Yes, to install and to use 20 tools, including unit conversion. Every install starts with a 7-day trial of PRO that ends on its own and never turns into a paid subscription. PRO itself is a monthly or annual Google Play subscription, priced in the store.

  • Android 7.0 or newer, on phones in portrait. The periodic table also turns to landscape for the full grid.

  • English, Deutsch, Français, Español, 日本語, 中文 and Русский. The app follows your phone's language, you can change it in Settings, and German, French, Spanish and Russian use a decimal comma everywhere, including charts, PDFs and exports.

  • On your phone. There is no account or sign-in, Android cloud backup is disabled and the app contains no ad libraries. Anonymous usage analytics are opt-in and off by default; calculator inputs, results, formulas, notes and search terms are never collected.

  • Android cloud backup is off, so nothing is copied to your Google account. On Android 12 and newer, a direct phone-to-phone transfer while you set up the new phone may still bring saved results, QC profiles and settings across; whether it does depends on the phone. To be sure you keep what matters, share it as a PDF, Excel or CSV file (PRO) before you switch. PRO itself comes back on the new phone with Restore Purchases in Settings, on the same Google account.

  • Calculations run on the phone. The internet is used to buy or restore PRO, to download 3D atom models the first time you open one, for update checks and, only if you opt in, for anonymous analytics.

  • With PRO, Share offers a PDF report, an Excel table or a CSV table. PDF reports follow your own template: logo, company, accreditation, report ID, operator, page numbers and up to two signature blocks.

  • Calculators are tested against independent reference implementations and published worked examples, and reference data such as atomic weights, spectral lines and interferences is checked against its sources. Where a result is valid but risky, the app shows a diagnostic hint rather than staying silent.

  • Yes. Use “Request a new tool or feature” on the Home screen, or write to support@labtoolsapp.com.