Kinematic ↔ dynamic viscosity

ν = η / ρ

Enter any two of the kinematic viscosity, the dynamic viscosity and the density: the third is calculated. A second card gives the viscosity index of an oil.

Kinematic ↔ dynamic viscosity

Enter any two — the third is calculated.

Viscosity and density are both temperature-dependent. Use values measured at the same temperature, or the result will not correspond to any real condition.

Viscosity index (ASTM D2270)

Both in mm²/s (cSt). VI is undefined below ν100 = 2.0.

mm²/s
mm²/s

Result

Enter any two — the third is calculated.

About this calculation

Runs in your browser

The calculation runs in your browser. Your inputs are kept in this browser's storage on this device so they are still here when you come back; Clear removes them.

Checked

Checked against: the relation ν = η / ρ in several unit pairs and the ASTM D2270 worked example.

Calculation version 088929cdc6c2, shared with the Android app.

Worked example

An oil has a dynamic viscosity of 20 cP and a density of 0.9 g/cm³.

ν = η / ρ = 20 / 0.9 = 22.2222 cSt

A mineral oil with ν = 73.30 mm²/s at 40 °C and 8.86 mm²/s at 100 °C has a viscosity index of 92. The Load example button fills in these values.

Formula

ν = η / ρ

ν
kinematic viscosity, m²/s in SI
η
dynamic viscosity, Pa·s in SI
ρ
density, kg/m³ in SI

In laboratory units the conversion needs no factor: ν in cSt equals η in cP divided by ρ in g/cm³, because 1 cP = 1 mPa·s and 1 g/cm³ = 1000 kg/m³ cancel to 1 cSt = 1 mm²/s. Enter any two and the third is calculated.

Assumptions and limits

  • Viscosity and density are both temperature-dependent. Use values measured at the same temperature, or the result will not correspond to any real condition.
  • Capillary viscometers measure kinematic viscosity directly, because the fluid falls under its own weight and the density is already in the measurement; rotational instruments measure dynamic viscosity.
  • Both in mm²/s (cSt). VI is undefined below ν100 = 2.0. VI is not defined below ν100 = 2.0 mm²/s.
  • L and H come from the standard's Annex X2 computation, accurate to within 0.1 % of Table 1. For specification purposes, confirm against the table.
  • ν at 40 °C must be greater than ν at 100 °C — check the two values are not swapped.

References

The relation ν = η / ρ is a definition and uses no tabulated data. The viscosity index follows ASTM D2270: L and H come from the computation in the standard's Annex X2 and are accurate to within 0.1 % of its Table 1, so confirm against the table for specification purposes.