Sieve mesh ↔ aperture converter

US No. ↔ aperture (ASTM E11)

Enter a US mesh number to read its aperture, or an aperture to find the sieve. When no standard sieve has that size, the two neighbours are given.

No.
Aperture in

US standard series (ASTM E11). Other series number differently: US No. 10 (2.00 mm) stands against Tyler 9 mesh, for example.

Result

Enter a mesh number or an aperture

About this calculation

Runs in your browser

The calculation runs in your browser. Your inputs are kept in this browser's storage on this device so they are still here when you come back; Clear removes them.

Checked

Checked against: the published aperture of several standard sieves, the lookup of an aperture between two sieves and the ends of the series.

Calculation version 088929cdc6c2, shared with the Android app.

Worked example

A US No. 100 sieve has a nominal aperture of 150 µm. In the other direction, 100 µm is not a standard sieve at all: it falls between No. 140 at 106 µm and No. 170 at 90 µm, so both are given.

The Load example button fills in the mesh number.

Formula

aperture = table lookup (ASTM E11 series)

A mesh number is not a unit. It designates one manufactured cloth whose aperture a standards committee chose, so there is no factor and nothing between two rows of the table. A mesh number converts to an aperture exactly; an aperture usually does not convert to a mesh number at all.

The formula going round, aperture = 25400 / mesh, is wrong: it ignores the wire, which takes up part of every pitch. At No. 200 it gives 127 µm against the standard's 75 µm.

Assumptions and limits

  • More than one series exists and they number differently. This is the US standard series of ASTM E11, whose nominal openings ISO 3310-1 shares. The Tyler Standard Screen Scale numbers the cloths differently: US No. 10 (2.00 mm) stands against Tyler 9 mesh, and US No. 12 (1.70 mm) against Tyler 10 mesh. Check which series your sieve set is certified to.
  • An aperture with no sieve of that size gets both neighbours and the nearest, not a number invented for the gap.
  • An aperture coarser or finer than the series says so and names the end sieve.
  • Successive sieves differ in aperture by about 2¼ (alternate ones by about √2, which is a factor of two in open area).
  • Nominal apertures are shown, not the tolerance of any particular sieve.

References

The series is the ASTM E11 standard series, as recorded in the calculation code of the LabTools Android app. The designations, openings and the Tyler numbering above are those of the Retsch International Comparison Table for Test Sieves, which sets ASTM E11, ISO 3310 and the Tyler Screen Scale side by side.

The calculation is the one used by the Sieve mesh ↔ µm converter in the app.